parameters: 

    1 Dimensions:. 63.5mm (L) * 38.5mm (W) * 18.5mm (H) 
    (2) positioning hole size: 58.5mm * 33.5mm hole diameter: 3.1mm 
    3 Relay load capacity:. 220V 10A AC or 30V 10A DC 
    4.5V Quiescent Current: 45mA Maximum power consumption: 130mA 
    5.12V Quiescent Current: 43mA Maximum power consumption: 90mA 
    6.24V Quiescent Current: 20mA Maximum power consumption: 43mAthe voltage needed.

 

Description

Product description:

Power on the product set trigger delay, loop timing delay, high and low trigger delay and self-locking, in one of the trigger points, with digital timer relay module with accurate delay, 18 kinds of functions available, the maximum pick 220V 10A AC or DC 30A 10A load, widely used in smart home automation control, product life testing, design applications, such as electronic enthusiasts

 

 the functional description:

This product has 18 kinds of function selection , specific functions are as follows :
The power ( electricity ) delay function part :

Function 1 :( timed off ) : When the power relay , the relay off after the delay time (with power will remain off ) , time of 1 sec -999 sec ( or 1-999 minutes ) between available tone , such as re-power or a trigger signal to the IN connector (supports high / low level trigger , external trigger switch button ) , you can interrupt and repeat the above functions ;


Function 2 :( timed pull ) : When you disconnect the power relay , after the delay time relay ( electric will remain pull ) , time of 1 sec -999 sec ( or 1-999 minutes ) between available tone , such as re-power or a trigger signal to the IN connector (supports high / low level trigger , external trigger switch button ) , you can interrupt and repeat the above functions ;


Function 3: ( re- timed pull off ) : When the power relay , pull time (T1) -999 seconds in 1 second ( or 1-999 minutes ) between adjustable , pull off the end of the time delay relay on, off time (T2) -999 seconds in 1 second ( or 1-999 minutes ) between adjustable off-delay after the end of the pull will remain , such as the re-power or a trigger signal to the iN connector ( supports high / low trigger , external trigger switch button ) , you can interrupt and repeat the above functions ;
 

Function 4 ( timed pull off again ) : On power relay off , off time (T1) -999 seconds in 1 second ( or 1-999 minutes ) between adjustable off-delay relay after together, pull time (T2) -999 seconds in 1 second ( or 1-999 minutes ) between adjustable , pull the end of the time delay relay will remain open, such as re-power or a trigger signal to the iN connector ( supports high / low trigger , external trigger switch button ) , you can interrupt and repeat the above functions ;
Cycle timing part :
 

Function 5 ( infinite loop timing mode 1 ) : After power relay , pull time (T1) -999 seconds in 1 second ( or 1-999 minutes ) between adjustable , pull off the end of the time delay relay , off time (T2) -999 seconds in 1 second ( or 1-999 minutes ) between adjustable off-delay relay after T1 time again to pull, this infinite loop. If re-power or a trigger signal to the IN connector (supports high / low level trigger , external trigger switch button ) , you can interrupt and repeat the above functions ;
 

Function 6 ( infinite loop timing mode 2 ) : After power relay off , off time (T1) -999 seconds in 1 second ( or 1-999 minutes ) between the adjustable delay after disconnect relay , pull time (T2) -999 seconds in 1 second ( or 1-999 minutes ) between adjustable pull after T1 time delay relay again to disconnect , this infinite loop. If re-power or a trigger signal to the IN connector (supports high / low level trigger , external trigger switch button ) , you can interrupt and repeat the above functions ;
 

Function 7 ( finite loop timing mode 1 ) : After power relay , pull time (T1) -999 seconds in 1 second ( or 1-999 minutes ) between adjustable , pull off the end of the time delay relay , off time (T2) -999 seconds in 1 second ( or 1-999 minutes ) between adjustable off-delay relay after T1 time again to pull, cycle times can be set at 1-999 times. If re-power or a trigger signal to the IN connector (supports high / low level trigger , external trigger switch button ) , you can interrupt and repeat the above functions ;
 

Function 8 ( finite loop timing mode 2 ) : After power relay off , off time (T1) -999 seconds in 1 second ( or 1-999 minutes ) between the adjustable delay after disconnect relay , pull time (T2) -999 seconds in 1 second ( or 1-999 minutes ) between the adjustable time delay relay after the pull- off again by the time T1 , the number of cycles can be set at 1-999 times. If re-power or a trigger signal to the IN connector (supports high / low level trigger , external trigger switch button ) , you can interrupt and repeat the above functions ;
Trigger delay feature sections:
 

Function 9 ( trigger timing off 1 ) : After power was disconnected state relay off , wait IN Interface trigger signal ( supports high / low trigger , external trigger switch button ) , when there is a trigger signal relay together, pull -999 second time in one second ( or 1-999 minutes ) between the adjustable end of the delay, the relay off , waiting for the next trigger signal , the delay in the iN port triggering invalid.
 

Function 10 ( pull a trigger timing ) : After power was disconnected state relay off , wait IN Interface trigger signal ( supports high / low trigger , external trigger switch button ) when the trigger signal , the relay remains disconnected state and delay, off-time in one second -999 seconds ( or 1-999 minutes ) between the adjustable end delay relay ( electric will remain pull ) , waiting for the next trigger signal delay in the iN port triggering invalid.
 

Function 11 ( trigger timing off 2 ) : After power was disconnected state relay off , wait IN Interface trigger signal ( supports high / low trigger , external trigger switch button ) , when there is a trigger signal relay together, pull -999 second time in one second ( or 1-999 minutes ) between the adjustable end of the delay, the relay off , waiting for the next trigger signal , the delay in the iN port trigger is valid.
 

Function 12 ( timed pull the trigger 2 ) : After power was disconnected state relay off , wait IN Interface trigger signal ( supports high / low trigger , external trigger switch button ) when the trigger signal , the relay remains disconnected state and delay, off-time in one second -999 seconds ( or 1-999 minutes ) between the adjustable end delay relay ( electric will remain pull ) , waiting for the next trigger signal effectively delay the iN port triggering.

12V LED Digital Display Adjustable Multifunction Delay Relay Module Timer

SKU: 151517590486
$10.99Price