Features:
1 new upgrade to version 2.0, the module functions by eight kinds before, increased to 18 kinds, to meet the needs of more applications;
2 increase supply anti-reverse feature, power will not damage the module wrong;
3 uses top-quality high-voltage power supply modules, discrete power supply before replacing the system more stable and reliable;
4 increased 0.1 seconds timing, timing accuracy from the previous 0.1 seconds, upgrade to 0.01 seconds;
5 increase in automatic power saving feature, users can independently set.

Tips: Function 1-8 on power-up self-start function 9-18 require high pulse signal (high duration is shorter than 20ms, hereinafter the same) trigger the start.
 


Function 1:
Timing Pick: After power, time delay relay pull T1, T1 between 0.1 seconds -270 hours adjustable, CH1 interface to a high level pulse signal, repeat the above functions;
 
Function 2:
Timing off: when the power relay, time delay relay disconnected T1, T1 between 0.1 seconds -270 hours adjustable, CH1 interface to a high level pulse signal, repeat the above functions;

Function 3:

Timing pull off again: After power relay to not pull, the delay time T1 reaches the relay is energized; pull the relay off after T2 arrival time, delay time T1 and T2 in 0.1 seconds -270 hours between adjustable, CH1 interface to a
High pulse signal, repeat the above functions;
 
Function 4:
Timing and then pull off: After power, immediately pull the relay, the relay off delay time T1 after arrival; T2 arrive after disconnecting time relay, -270 hour in 0.1 seconds delay time between T1 and T2 adjustable to CH1 interface a high pulse signal, repeat the above functions;
 
Function 5:
Infinite loop timing mode 1: After power relay to not pull, after the delay time T1 reaches the relay is energized; pull the relay off after time T2 arrives, and then repeat the above condition, the delay time T1 and T2 at 0.1 adjustable between second -270 hours, giving a high level pulse signal CH1 interface, you can restart the above functions;
 
Function 6:
Infinite loop timing mode 2: After power, immediately pull the relay delay time T1 reaches the relay off; arrive after disconnecting time T2 relay, and then repeat the above condition, the delay time T1 and T2 in 0.1 seconds adjustable between -270 hours, giving a high level pulse signal CH1 interface, you can restart the above functions;
 
Function 7:
Finite loop timing mode 1: 5 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times to CH1 interface a high pulse signal, the above functions can be re-started;
 
Function 8:
Finite loop timing mode 2: 6, on the basis of the function, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times to CH1 interface a high pulse signal, the above functions can be re-started;
 
Function 9:
Latching relay modes: CH1 interface to relay a high level pulse signal, relay, give a high pulse signal relay disconnected.
 
Function 10:
Trigger relay modes: CH1 interface to a high signal relay, relay, high disappear, relay disconnected.
 
Function 11:
Pull the trigger timing: After power relay does not act, a high-level interface to CH1 pulse signal, the delay time relay pull T1, T1 between 0.1 seconds -270 hours adjustable, repeating a high level interface to CH1 pulse signal, repeat the above function;
 
Function 12:
Trigger timing off: After power relay does not act, a high-level interface to CH1 pulse signal relay, the relay off delay time T1, T1 between 0.1 seconds -270 hours adjustable, repeat to CH1 interface a high pulse signal, repeat the above functions;
 
Function 13:
Pull the trigger timing then disconnect: After power relay does not act, CH1 interface to a high level pulse signal, the delay time T1 reaches the relay is energized; pull the relay off after T2 arrival time, delay time T1 and T2 between 0.1 seconds -270 hours adjustable, repeat CH1 interface to a high level pulse signal, repeat the above functions;
 
Function 14:
Disconnect and then pull the trigger timing: After power relay does not act, a high-level interface to CH1 pulse signal, immediately pull the relay, the relay off delay time T1 after arrival; T2 arrive after disconnecting time relay, delay time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a high level pulse signal, repeat the above functions;

Function 15:
Infinite loop timing mode 1: After power relay does not operate to a high level pulse signal CH1 interface, the delay time T1 reaches the relay is energized; pull off the relay arrival time T2, and then repeat the above condition, the extension when the time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a high level pulse signal, the above functions can be re-started;

Function 16:
Infinite loop timing mode 2: After power relay does not act, a high-level interface to CH1 pulse signal, immediately pull the relay, the relay off delay time T1 after arrival; break time T2 after reaching relay, then repeat the above condition, the delay time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a high level pulse signal, the above functions can be re-started;
 
Function 17:
Finite loop timing mode 1: 15 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times, repeating to CH1 interface a high pulse signal, the above functions can be re-started;

Function 18:
Finite loop timing mode 2: 16 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times, repeating to CH1 interface a high pulse signal, the above functions can be re-started;
 
Module Interface :
 
Module control terminal: there are 3-wire interface, all interfaces are terminal, user-friendly
1, DC +: DC power positive (with 5V, 12V and 24V modules to choose from)
2, DC-: DC power supply negative
3, CH1: input detection interface, high effective
 
Relay outputs: There are 3-wire interface, all interfaces are terminals
1, NO: normally open relay interface and relay before the vacant after the pull short and COM1
2, COM: Common Interface Relays
3, NC: normally closed relay interface and relay COM1 shorted before and after the pull-vacant
Load capacity: normally open port maximum load capacity: DC 0-30V / 10A, AC 0-250V / 10A
NC port maximum load capacity: DC 0-28V / 10A, AC 0-125V / 10A
 
Package Size: 15cm x 10cm x 5cm (5.91in x 3.94in x 1.97in)